PRODUCT INTRODUCTION

OM-LPC 521/4

Application:
• calibration and adjustment of analog and digital manometers, pressure measurement molders, pressure switches and overpressure protection devices
• simulating overpressure and vacuum
• measuring current and voltage
• gives auxiliary power of 24 V DC
• testing procedures can be pre-defined and executed
• converting pressure to current or voltage
• converting current or voltage to pressure

Equipment: built-in precision pressure gauge type LPC 300
exchangeable pressure sensors: over, under and absolute pressure

Full-scale reading: to 30 bar

OM-LPC 521/4

Application:
• calibration and adjustment of analog and digital manometers, pressure measurement molders, pressure switches and overpressure protection devices
• simulating overpressure and vacuum
• measuring current and voltage
• gives auxiliary power of 24 V DC
• testing procedures can be pre-defined and executed
• converting pressure to current or voltage
• converting current or voltage to pressure

Equipment: built-in precision pressure gauge type LPC 300
exchangeable pressure sensors: over, under and absolute pressure

Full-scale reading: to 30 bar

OMHE 731_P

Application:
• calibration and adjustment of analog and digital manometers, pressure measurement molders, pressure switches and overpressure protection devices
• simulation of hydraulicn pressures up to 450 bar

Equipment:
• digital LC display

Full-scale reading: to 450 bar

Hydraulic oil or water can be used as the testing media. After the test set-up has been deaerated with the built-in low-pressure pump, the test pressure is built up with a smooth-running, high-pressure, hand-lever pump, the exact fine adjustment with a variable volume.

OMHE 731_P

Application:
• calibration and adjustment of analog and digital manometers, pressure measurement molders, pressure switches and overpressure protection devices
• simulation of hydraulicn pressures up to 450 bar

Equipment:
• digital LC display

Full-scale reading: to 450 bar

Hydraulic oil or water can be used as the testing media. After the test set-up has been deaerated with the built-in low-pressure pump, the test pressure is built up with a smooth-running, high-pressure, hand-lever pump, the exact fine adjustment with a variable volume.

dz¼Ó¼¾¼­

* Dimension : 224¨ª x 327mmH, Max. housing 80¨ª
* ÀÛµ¿¿Âµµ : -35 ~ 80¡É
* Max. load : 60m/s
* ÃøÁ¤¹üÀ§ : 0 ~ 41m/s
* ¹ÝÀÀ±âÁ¡ : 0.8m/s
* Response length : app. 3m (À¯¼ÓV = 5m/sÀÏ °æ¿ì)
* Á¤È®µµ : ¡¾0.3m/s (À¯¼ÓV > 15m/s)
* Output : 0 ~ 1mA
* Á¦Ç°»ç¾ç¿¡ µû¶ó ¸ðµ¨ÀÌ ´Þ¶óÁú ¼ö ÀÖÀ½.
* 4034 Series : 4021 + Á֯ļö Ãâ·Â ¹× Add. Output
* 4035 Series : 4034 + open collector with heating ¹× add. output
* 3091 Series : 4035 + Reed SW output ¹× Generator output

ä³ÎÅå
ä³ÎÅå
»ó´ãÇϱâ
½º¸¶Æ®Ä®±³Á¤°ü¸®½Ã½ºÅÛ
½º¸¶Æ®Ä®
±³Á¤°ü¸®½Ã½ºÅÛ
°ßÀû¹®ÀÇÇϱâ
°ßÀû
¹®ÀÇÇϱâ
½º¸¶Æ®½ºÅä¾î
ÄÚ¸ÞÃ÷
½º¸¶Æ®½ºÅä¾î
À¯Æ©ºê
ÄÚ¸ÞÃ÷
À¯Æ©ºê
¡ã
TOP