PRODUCT INTRODUCTION

Tecal 140S -40 ~ 140¡ÆC / 0.05¡ÆC ¾ÈÁ¤µµ

Temperature range 45¡ÆC below ambient to 140¡ÆC (typically -20¡ÆC in an ambient of 25¡ÆC)
Temperature range with CH-5 unit -40¡ÆC to 140¡ÆC (using Chilled water supply through heatsinks)
Display Accuracy ¡¾0.3¡ÆC
Temperature Uniformity ¡¾0.2¡ÆC
Measuring zone 0 to 50mm from base of well
Temperature Stability ¡¾0.05¡ÆC ( after 10 mins)
Display resolution 0.1¡ÆC or 0.1 ¡ÆF
Display units Selectable ¡ÆC or ¡ÆF
PC Interface RS-232
Heating rate 20¡ÆC to 100¡ÆC 5 minutes
Cooling rate 100¡ÆC to 0¡ÆC 9 minutes
Ramp Rate ¡ÆC per min 0.1 to 10 on H version
Switch test on H model
Large well ¨ª38mm x 135 mm deep lnserts
Fan Cooling Automatic
Additional Cooling Water Cooling channels on S and H models
Carry case Soft carry case included
Dimensions L x W x H (mm) 285 x 190 x 426
Weight 14kg (S) 14.4kg (H)

Tecal 650S&H 45 ~ 650¡ÆC / 0.09¡ÆC ¾ÈÁ¤µµ

emperature range 25¡ÆC above ambient to 650¡ÆC
Display Accuracy ¡¾0.4¡ÆC
Temperature Uniformity ¡¾1¡ÆC
Measuring zone 0 to 50mm from base of well
Temperature Stability ¡¾0.09¡ÆC ( after 10 mins)
Display resolution 0.1¡ÆC or 0.1 ¡ÆF
Display units Selectable ¡ÆC or ¡ÆF
PC Interface RS-232
Heating rate 20¡ÆC to 400¡ÆC 35 minutes
Cooling rate 400¡ÆC to 100¡ÆC 30 minutes
Ramp Rate ¡ÆC per min 0.1 to 10 on H version
Switch test on H model
Large well ¨ª38mm x 152 mm deep lnserts
Fan Cooling Automatic
Fast Cooling Rapid Water Cooling Probe - Compatible Option
Carry case Soft carry case included
Dimensions L x W x H (mm) 285 x 190 x 426
Weight 11.8kg (S) 12.2kg (H)

Tecal 425S&H 40 ~ 425¡ÆC / 0.05¡ÆC ¾ÈÁ¤µµ

* Temperature range 20¡ÆC above ambient to 425¡ÆC
* Display Accuracy ¡¾0.3¡ÆC
* Temperature Uniformity ¡¾0.2¡ÆC
* Measuring zone 0 to 50mm from base of well
* Temperature Stability ¡¾0.05¡ÆC ( after 10 mins)
* Display resolution 0.1¡ÆC or 0.1 ¡ÆF
* Display units Selectable ¡ÆC or ¡ÆF
* PC Interface RS-232
* Heating rate 20¡ÆC to 400¡ÆC 15 minutes
* Cooling rate 400¡ÆC to 100¡ÆC 25 minutes
* Ramp Rate ¡ÆC per min 0.1 to 10 on H version
* Switch test on H model
* Large well ¨ª38mm x 135 mm deep lnserts
* Fan Cooling Automatic
* Fast Cooling Rapid Water Cooling Probe - Compatible Option
* Carry case Soft carry case included
* Dimensions L x W x H (mm) 285 x 190 x 426
* Weight 9.2kg (S) 9.6kg (H)

Tecal 700X 45 ~ 700¡ÆC / 0.005¡ÆC ¾ÈÁ¤µµ

Temperature range Ambient +25¡ÆC to 700¡ÆC
Display Accuracy ¡¾0.25¡ÆC at 700¡ÆC
Display Accuracy ¡¾0.15¡ÆC up to 660¡ÆC
Temperature Uniformity ¡¾0.04¡ÆC radial and ¡¾0.4¡ÆC axial
Temperature Stability ¡¾0.03¡ÆC ( at 700¡ÆC) and ¡¾0.005¡ÆC ( at 100¡ÆC)
Display resolution 0.01¡ÆC across range ( 0.01 ¡ÆF to 999.9¡ÆF then 0.1 to 1292¡ÆF)
Display units Selectable ¡ÆC or ¡ÆF
Switch test Ramp rate (¡ÆC or ¡ÆF per min) Selectable 0.1 to 10.0¡ÆC or 0.1 to 18.0 ¡ÆF
PC Interface USB
Heating rate ambient to 700¡ÆC 25 minutes
Cooling rate 700 to 100¡ÆC 30 minutes
Large block with bores and slim lnsert (Metric) ¨ª63mm with 6 off bores ¨ª15 10 8 6 4.5 3mm x 150 mm deep
Large block with bores and slim lnsert (Imperial) ¨ª63mm with 6 off bores ¨ª5/8¡± 3/8¡± 5/16¡± 1/4¡± 3/16¡± 1/8¡± x 150 mm deep
Fan Cooling Automatic
Safety over-temperature cut-out Yes
Fast Cooling Rapid Water Cooling Probe - Compatible Option
Dimensions L x W x H (mm) 285 x 190 x 426
Weight 10.0kg