HOME > Á¦Ç°¼Ò°³ > INDUSTRY > °¡½º °ËÃâ±â / »ê¼Ò ºÐ¼®±âXTP601 Series¼ö¼Ò, Áú¼Ò, °ø±â µîÀÇ °¡½º¸¦ ÃøÁ¤Çϱâ À§ÇÑ °ß°íÇÏ°í ¼±ÇüÀÇ ¾ÈÁ¤ÀûÀÎ »ê¼Ò ºÐ¼®±âÀÔ´Ï´Ù. ¼¾¼ÀÇ ÇÏ¿ì¡Àº Æ°Æ°ÇÑ ÄÉÀ̽º·Î µÇ¾î ÀÖÀ¸¹Ç·Î, ´Ù¾çÇÑ ¿ëµµ¿¡ ÀûÇÕÇÕ´Ï´Ù. È¿° ¹æÁ¦±â°¡ ¼³Ä¡µÈ °æ¿ì ºÐ¼®±â´Â ¹æÆø ±â´ÉÀÌ ÀÖÀ¸¹Ç·Î À§ÇèÁö¿ª¿¡¼ »ç¿ëÇϱâ ÀûÇÕÇÕ´Ï´Ù.
Á¦Ç°¹®ÀÇ : 031-732-5990, sales@komets.co.kr
Performance Measurement Technology Thermo-paramagnetic oxygen sensor Gas Process and non-condensing sample with particles < 3 ¥ìm Measurement Range Selectable from 0-1% up to 0-50% O2 and 80/90 - 100% Display Resolution 0.01% Display Type Backlit LCD Accuracy Excluding Suppressed Zero Ranges < ¡¾1% of span or ¡¾0.02% O2 whichever is greater Accuracy For Suppressed Zero Ranges (80/90 - 100%) < 0.2% O2 Response Time (T90) with High Speed Response (HSR) Enabled < 15 seconds Repeatability ¡¾0.2% of span or 0.01% O2 whichever is greater Linearity ¡¾0.5% of span or 0.05% O2 whichever is greater Zero Stability ¡¾0.25% of span per month Span Stability ¡¾0.25% of span per month Sample Flow Rate 100 to 600 ml/min Sample Flow Effect
(calibrated at 300 ml/min)< 1% of span for flows: 100 to 600 ml/min Sample Pressure 0 to 3 barg (43 psig) Sample Temperature 0 to +55¡ÆC max (+45¡ÆC for standard cell) Sample Cell Temperature Standard +50¡ÆC (Optional +55¡ÆC and +60¡ÆC) Background Gas Unit can be calibrated in a user-defined background gas to increase the accuracy Electrical input/output Analog Inputs 2 off 4-20 mA inputs
One for an external sensor that can be displayed on the screen
One to act as an active compensation for the process conditionsAnalog Outputs 2 off 4-20 mA outputs (isolated) Output Ranges Primary range is set to the calibrated range of the instrument
The second is user selectable within the primary rangeAlarms 2 off single pole changeover (SPCO) relays for O2 concentration (250 V, 5 A max) Datalogging The user can use the digital communications to log the output from the analyzer
The unit will store 40 alarm points and the min/max O2 concentrations with date and time stampDigital Communications MODBUS RTU over RS485 Protocol Power Supply 24 V DC; 1.5 A max Operating Conditions Ambient Temperature -20 to +55¡ÆC (dependent on configuration) Mechanical Specification Warm Up Time < 30 minutes Stabilization Time 15 minutes Dimensions 234 x 234 x 172mm (w x d x h) Weight 9.7kg Wetted Materials 316 & 430F stainless steel, boroscillicate glass, platinum, 3M 2216, plus O-ring O-Ring Materials Viton, Silicone or Ekraz Gas Connection 1/4¡± NPT, 1/4¡± tube or 6mm tube Ingress Protection IP66, NEMA 4X Hazardous Area Classifications ATEX II 2 G Ex d IIB+H2 T3 Gb IEC Ex II 2 D Ex tb IIIC T137¡ÆC Db IP66 T amb -40¡ÆC to +55¡ÆC cCSAus Class I, Division 1, Groups B,C,D