HOME > Á¦Ç°¼Ò°³ > INDUSTRY > ½Àµµ(³ëÁ¡) & ¼öºÐŬ·¡½Ä µðÀÚÀÎ ³ëÁ¡Æ®·£½º¹ÌÅÍ-100 ~ 20¡Édp / Á¤È®µµ ¡¾1~2¡Édp
ÀüÅëÀûÀÎ µðÀÚÀÎÀÇ ¿À·¡µÈ ³ëÁ¡¼¾¼·Î ¸ð´ÏÅ͸¦ ÀÌ¿ëÇÏ¿© ½Ç½Ã°£ È®Àΰ¡´É.
°ø±â ¶Ç´Â °øÁ¤°¡½ºÀÇ ¼öºÐÇÔ·®À» ÃøÁ¤.ºÐ¼®Çϱ⿡ ¿ëÀÌ
ÇöÀç´Â Easidew ½Ã¸®Áî·Î ¸¹ÀÌ ´ëüµÇ°í ÀÖÀ½
* ÄÚ¸ÞÃ÷ ³ëÁ¡±³Á¤½Ã½ºÅÛÀ» ÀÌ¿ëÇÏ¿© Á¡°Ë/±³Á¤¼ºñ½º Á¦°øÁ¦Ç°¹®ÀÇ : 031-732-5990, sales@komets.co.kr
Sensor Measurement Range -100 to +20¡ÆCdp Accuracy (dew point) ¡¾1¡ÆC from -60 to +20¡ÆCdp
¡¾2¡ÆC from -100 to -60¡ÆCdpEnclosure Stainless steel Ingress Protection IP66 in accordance with standard BS EN 60529:1992
NEMA 4 in protection and accordance with standard NEMA 250-2003Operating Temperature -40 to +60¡ÆC compensated over -20 to +40¡ÆC Storage Temperature -40 to +109¡ÆC Operating Pressure From vacuum to 40 MPa (400 barg/5801 psig) (max) Flow Rate 1 to 5 Nl/min Gas Velocity 0 to 10m/sec Process Connection 5/8" UNF parallel thread Sensor Calibration Traceable to UKAS and NIST Analyzer Measurement Units ¡ÆC, ¡ÆF dew point; ppmV with user selectable range and resolution; lb/MMscf range dependent on pressure (natural gas); g/m©ø (natural gas)
Digital processing and linearization with active or passive pressure compensationResolution 0.1 ¡ÆC from -80 to +20¡ÆCdp
1¡ÆC from -100 to -80¡ÆCdpSecondary Measurement Variable Pressure using an optional external transducer over a range of 0-45 MPa (450 barg/6527 psig
Completely user-configurable for any industry standard transducer with an 4-20 mA output
Automatic compensation for ppmV, lbs/MMscf and g/m©ø unitsAlarm Relays Two user adjustable isolated 10A form 'C' rated at 240 V AC or 24 V DC Outputs: Analog 4-20 mA as standard (max load 500 ¥Ø) user configurable and scalable Digital RS232 Power Supply Universal 85 to 265 V AC, 50/60 Hz or 95 to 370 V DC Operating conditions Operating Temperature Analyzer 0 to +50¡ÆC Sensor -20 to +50¡ÆC (-5 to +122¡ÆF) Ingress Protection Analyzer IP54 (NEMA 12) standard (front panel only)
IP66 (NEMA4) with optional cover (front panel only)Sensor IP66 (NEMA4) Options Outputs: Analog 0-20 mA optional (max load 500 ¥Ø) 0-10 V optional (min load 5 K ¥Ø) both user-configurable and scalable Digital RS485: provides 2-way communication - full data access to user and total instrument configuration Alarm Relays 1 or 2 additional 5 A relays (max 4 total) n/o type fully user configurable and adjustable over the full range, full choice of units and sensor fault alarm functions Power Supply 18 to 36 V AC; 9 to 60 V DC Cable Standard 2m (1200m max)