PRODUCT INTRODUCTION

Ç¥ÁØ ºÐµ¿½Ä ¾Ð·Â°è KLPB ½Ã¸®Áî

KLPB ½Ã¸®Áî´Â °ø¾Ð/À¯¾Ð 1Â÷ Ç¥Áرâ·Î ¾²ÀÌ´Â ºÐµ¿½Ä ¾Ð·Â°èÀÔ´Ï´Ù.
-°íÁ¤¹ÐÀÇ 1Â÷ Ç¥Áرâ·Î½á ¶Ù¾î³­ ¾Ð·Â ¾ÈÁ¤È­ ¹× Àå±â ¾ÈÁ¤¼ºÀ» ÀÚ¶ûÇÕ´Ï´Ù.
¶ÇÇÑ ¾Ð·Â ¹ß»ý±â/Á¶Àý±â°¡ ºÐ¸®ÇüÀ¸·Î µÇ¾î ÀÖ¾î ¾Ð·Â ¹ß»ý±â/Á¶Àý±â¸¦ µ¶¸³ÀûÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

KOLAS °ø¾ÐÇ¥ÁØ ºÐµ¿½Ä ¾Ð·Â°è CPB 5000

ÃÑ ÃøÁ¤ ºÒÈ®µµ 0.008 % of Reading ÀÇ ºÐµ¿½Ä ¾Ð·Â°è
ÃÖ´ë 100 bar ÀÇ °ø¾Ð ¶Ç´Â ÃÖ´ë 400 bar ±îÁöÀÇ ±âü¸¦ ÀÌ¿ëÇÑ °ø¾Ð¿ë ºÐµ¿½Ä ¾Ð·Â Ç¥Áرâ
¾Ð·Â °è±âÀÇ ½ÃÇè, Á¶Á¤ ¹× ±³Á¤À» À§ÇÑ °øÀå ¹× ±³Á¤ ±â°ü¿¡ ´ëÇÑ Ç¥ÁØ Àåºñ (Reference instrument)
Àüü µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱ⠶ÇÇÑ ÀûÇÕ

KOLAS À¯¾ÐÇ¥ÁØ ºÐµ¿½Ä ¾Ð·Â°è CPB 5800

ÃøÁ¤ ºÒÈ®µµ 0.006 % of Reading ÀÇ ºÐµ¿½Ä ¾Ð·Â°è
ÃÖ´ë 1,400 bar (20,000 psi)ÀÇ À¯¾Ð ¹üÀ§¿¡¼­ ¾Ð·Â ´«±Ý º¸Á¤À»À§ÇÑ ±âº» Ç¥ÁØPSI
¾Ð·Â ÃøÁ¤ ±â±â¿¡ ´ëÇÑ Å×½ºÆ® ¹× °Ë±³Á¤ °øÀå ¹× ±³Á¤ ±â°üÀ» À§ÇÑ ±âÁØ ±â±â
¿Ïº®ÇÑ µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱâ ÀûÇÕ

½Ì±ÛÇǽºÅæ °ø¾Ð ºÐµ¿½Ä ¾Ð·Â°è CPB 3500

ÃøÁ¤ºÒÈ®µµ ÃÖ¼Ò 0.015 ... 0.006 % ÀÇ ºÐµ¿½Ä ¾Ð·Â°è
¾Ð·Â ´«±Ý ±³Á¤À» À§ÇÑ 1Â÷ Ç¥ÁØ ±â±â (°ø¾Ð ¹üÀ§: -1 ... 120 bar / -14,5 ... 1.600 lb/in©÷)
¾Ð·Â ÃøÁ¤ ±â±âÀÇ ±³Á¤, Å×½ºÆ®, Á¶Á¤À» À§ÇÑ °øÀå ¹× ±³Á¤½Ç ±âÁØ ±â±â (Reference instrument)
ÇöÀå »ç¿ë¿¡ ÀûÇÕÇÑ ¿ÏÀü µ¶¸³Çü ½Ã½ºÅÛ

½Ì±ÛÇǽºÅæ À¯¾Ð ºÐµ¿½Ä ¾Ð·Â°è CPB 3800

ÃøÁ¤ºÒÈ®µµ 0.025% of Reading ÀÇ ºÐµ¿½Ä ¾Ð·Â°è
ÃÖ´ë 1,200 bar (16,000 PSI) ÀÇ À¯¾Ð ¹üÀ§±îÁö ¾Ð·Â ½ºÄÉÀÏÀ» ±³Á¤Çϱâ À§ÇÑ ±âº» Ç¥ÁØ (Primary standard)
¾Ð·Â °è±âÀÇ ½ÃÇè, Á¶Á¤ ¹× ±³Á¤À» À§ÇÑ °øÀå ¹× ±³Á¤ ±â°ü¿¡ ´ëÇÑ Ç¥ÁØ Àåºñ (Reference instrument)
Àüü µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱ⠶ÇÇÑ ÀûÇÕ

±¹°¡Ç¥ÁØ±Þ °íÁ¤¹Ð ºÐµ¿½Ä ¾Ð·Â°è CPB 6000

ÃøÁ¤ ºÒÈ®µµ 0.002 % of Reading ÀÇ °íÁ¤¹Ð ºÐµ¿½Ä ¾Ð·ÂÇ¥ÁØÀåºñ
¾Ð·Â ÃøÁ¤ ±â±âÀÇ ½ÃÇè, Á¶Á¤ ¹× ±³Á¤À»À§ÇÑ °øÀå ¹× ±³Á¤ ±â°ü¿¡ ´ëÇÑ ±âÁØ ±â±â (Reference instrument)
ÇǽºÅæ ½Ç¸°´õ ½Ã½ºÅÛÀÇ À¯È¿ ¸éÀûÀ» °áÁ¤ÇÐ À§ÇÑ Å©·Î½º Ç÷ÎÆ® ÃøÁ¤ (Cross-float measurement)
Àüü µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱ⠶ÇÇÑ ÀûÇÕ

±¹°¡Ç¥ÁØ±Þ °íÁ¤¹Ð Â÷¾Ð ºÐµ¿½Ä ¾Ð·Â°è CPB 6000DP

ÃÖ´ë 800 bar / 11,600 psi ÀÇ °ø¾Ð ÃøÁ¤ ¹üÀ§ (= Á¤¾Ð + Â÷¾Ð) ÀÇ °í±Þ 1Â÷ Ç¥Áرâ
Â÷µ¿Çü ¼¾¼­ ¹× Æ®·£½º¹ÌÅÍÀÇ Å×½ºÆ®¿Í ±³Á¤
Æ÷ÁöƼºê ¶Ç´Â ³×°¡Æ¼ºê Â÷¾Ð (Positive or negative differential pressure)
ÇǽºÅæ ½Ç¸°ÅÍ ½Ã½ºÅÛ À¯È¿ ¸éÀû °áÁ¤À» À§ÇÑ Å©·Î½º Ç÷ÎÆ® ÃøÁ¤(Cross-float measurement)

KOLAS Â÷¾ÐÇ¥ÁØ ºÐµ¿½Ä ¾Ð·Â°è CPB 5600DP

ÃÑ ÃøÁ¤ ºÒÈ®µµ: 0.0001 % (1 ppm) ÀÇ Á¤¾ÐÀ» ´õÇÑ 0.008 % ÀÇ Â÷¾Ð
Á¤¾Ð ½Ã, Â÷¾Ð °è±âÀÇ ±³Á¤À» À§ÇÑ ±âº» Ç¥ÁØ (Primary standard)
¾Ð·Â °è±âÀÇ ½ÃÇè, Á¶Á¤ ¹× ±³Á¤À» À§ÇÑ °øÀå ¹× ±³Á¤ ±â°ü¿¡ ´ëÇÑ Ç¥ÁØ Àåºñ (Reference instrument)
Àüü µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱ⠶ÇÇÑ ÀûÇÕ

°í¾Ð¿ë ºÐµ¿½Ä ¾Ð·ÂÇ¥ÁØ CPB 5000HP

ÃøÁ¤ ºÒÈ®µµ 0.02 % of Reading ÀÇ °í¾Ð¿ë ºÐµ¿½Ä ¾Ð·Â°è
ÃÖ´ë 5000 bar (70,000 PSI) À¯¾Ð ¹üÀ§±îÁöÀÇ ¾Ð·Â ½ºÄÉÀÏÀ» Á¤ÀÇÇϱâ À§ÇÑ ±âº» Ç¥ÁØ (Primary standard)
¾Ð·Â °è±âÀÇ ½ÃÇè, Á¶Á¤ ¹× ±³Á¤À» À§ÇÑ °øÀå ¹× ±³Á¤ ±â°ü¿¡ ´ëÇÑ Ç¥ÁØ Àåºñ (Reference instrument)
Àüü µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱ⠶ÇÇÑ ÀûÇÕ

°í¾Ð¿ë À¯¾Ð ºÐµ¿½Ä ¾Ð·Â°è CPB 3800HP

ÃøÁ¤ ºÒÈ®µµ ÃÖ´ë 0.025 % of Reading ÀÇ ºÐµ¿½Ä ¾Ð·Â°è
ÃÖ´ë 1,200 bar (16,000 PSI) ÀÇ À¯¾Ð ¹üÀ§±îÁö ¾Ð·Â ½ºÄÉÀÏÀ» ±³Á¤Çϱâ À§ÇÑ ±âº» Ç¥ÁØ (Primary standard)
¾Ð·Â °è±âÀÇ ½ÃÇè, Á¶Á¤ ¹× ±³Á¤À» À§ÇÑ °øÀå ¹× ±³Á¤ ±â°ü¿¡ ´ëÇÑ Ç¥ÁØ Àåºñ (Reference instrument)
Àüü µ¶¸³Çü ½Ã½ºÅÛ, ÇöÀå¿¡¼­ »ç¿ëÇϱ⠶ÇÇÑ ÀûÇÕ

Áø°ø ¹«¼±µ¥ÀÌÅͷΰŠPirani Vacuum Logger ½Ã¸®Áî

³»¿­¿Âµµ 85¡ÆC ±îÁö Àý´ë¾Ð 0,001 mbar to 1200 mbar ÃøÁ¤
³·Àº ¼ÒºñÀü·Â ¹èÅ͸® ¼ö¸í¿¬Àå
»ç¿ëÀÚ°¡ Á÷Á¢ ¹èÅ͸® ±³Ã¼°¡´ÉÇÑ ½¬¿î À¯Áöº¸¼ö
¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇÑ ¹èÅ͸® ÀÜ·®È®ÀÎ
°øÀαâ°ü ¼Ò±Þ¼ºÀ» À¯ÁöÇÑ ±³Á¤¼ºÀû¼­¿Í -60¡ÆC ¹üÀ§±îÁö ±³Á¤°¡´É

ÇǶó´Ï Áø°ø µ¥ÀÌÅͷΰŠPirani Vacuum Logger

¾Ð·Â ¿Âµµ ÃøÁ¤¹üÀ§ Àý´ë¾Ð 0.001 mbar ~ 1200 mbar / -60 ¡ÆC ~ +85 ¡ÆC
ISO Ç¥Áر԰ݿ¡ µû¸¥ ¼ÒÇÁÆ®¿þ¾î¸¦ ÀÌ¿ëÇÑ º¸°í¼­ Ãâ·Â (µ¥ÀÌÅÍ ¼öÁ¤ºÒ°¡)
¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇÑ ¹èÅ͸®ÀÜ·® È®Àΰ¡´É. »ç¿ëÀÚ°¡ Á÷Á¢±³Ã¼ °¡´ÉÇÑ ½¬¿î ÀÛ¾÷
FDA ±Ô°Ý¿¡ µû¸¥ ¹ë¸®µ¥ÀÌ¼Ç TS Manager ¼ÒÇÁÆ®¿þ¾î¿Í »ç¿ë°¡´É