PRODUCT INTRODUCTION

XTP601 Series

¼ö¼Ò, Áú¼Ò, °ø±â µîÀÇ °¡½º¸¦ ÃøÁ¤Çϱâ À§ÇÑ °ß°íÇÏ°í ¼±ÇüÀÇ ¾ÈÁ¤ÀûÀÎ »ê¼Ò ºÐ¼®±âÀÔ´Ï´Ù. ¼¾¼­ÀÇ ÇÏ¿ì¡Àº Æ°Æ°ÇÑ ÄÉÀ̽º·Î µÇ¾î ÀÖÀ¸¹Ç·Î, ´Ù¾çÇÑ ¿ëµµ¿¡ ÀûÇÕÇÕ´Ï´Ù. È­¿° ¹æÁ¦±â°¡ ¼³Ä¡µÈ °æ¿ì ºÐ¼®±â´Â ¹æÆø ±â´ÉÀÌ ÀÖÀ¸¹Ç·Î À§ÇèÁö¿ª¿¡¼­ »ç¿ëÇϱâ ÀûÇÕÇÕ´Ï´Ù.

»ó¼¼¼³¸í

Performance
Measurement TechnologyThermo-paramagnetic oxygen sensor
GasProcess and non-condensing sample with particles < 3 ¥ìm
Measurement RangeSelectable from 0-1% up to 0-50% O2 and 80/90 - 100%
Display Resolution0.01%
Display TypeBacklit LCD
Accuracy Excluding Suppressed Zero Ranges< ¡¾1% of span or ¡¾0.02% O2 whichever is greater
Accuracy For Suppressed Zero Ranges (80/90 - 100%)< 0.2% O2
Response Time (T90) with High Speed Response (HSR) Enabled< 15 seconds
Repeatability¡¾0.2% of span or 0.01% O2 whichever is greater
Linearity¡¾0.5% of span or 0.05% O2 whichever is greater
Zero Stability¡¾0.25% of span per month
Span Stability¡¾0.25% of span per month
Sample Flow Rate100 to 600 ml/min
Sample Flow Effect 
(calibrated at 300 ml/min)
< 1% of span for flows: 100 to 600 ml/min
Sample Pressure0 to 3 barg (43 psig)
Sample Temperature0 to +55¡ÆC max (+45¡ÆC for standard cell)
Sample Cell TemperatureStandard +50¡ÆC (Optional +55¡ÆC and +60¡ÆC)
Background GasUnit can be calibrated in a user-defined background gas to increase the accuracy
Electrical input/output
Analog Inputs2 off 4-20 mA inputs 
One for an external sensor that can be displayed on the screen
One to act as an active compensation for the process conditions
Analog Outputs2 off 4-20 mA outputs (isolated)
Output RangesPrimary range is set to the calibrated range of the instrument
The second is user selectable within the primary range
Alarms2 off single pole changeover (SPCO) relays for O2 concentration (250 V, 5 A max)
DataloggingThe user can use the digital communications to log the output from the analyzer
The unit will store 40 alarm points and the min/max O2 concentrations with date and time stamp
Digital CommunicationsMODBUS RTU over RS485 Protocol
Power Supply24 V DC; 1.5 A max
Operating Conditions
Ambient Temperature-20 to +55¡ÆC (dependent on configuration)
Mechanical Specification
Warm Up Time< 30 minutes
Stabilization Time15 minutes
Dimensions234 x 234 x 172mm (w x d x h)
Weight9.7kg
Wetted Materials316 & 430F stainless steel, boroscillicate glass, platinum, 3M 2216, plus O-ring
O-Ring MaterialsViton, Silicone or Ekraz
Gas Connection1/4¡± NPT, 1/4¡± tube or 6mm tube
Ingress ProtectionIP66, NEMA 4X
Hazardous Area Classifications
ATEXII 2 G Ex d IIB+H2 T3 Gb
IEC ExII 2 D Ex tb IIIC T137¡ÆC Db IP66 T amb -40¡ÆC to +55¡ÆC
cCSAusClass I, Division 1, Groups B,C,D